TAURUS SIGMAX (Distribution Line Analyser)
TAURUS SIGMAX (Distribution Line Analyser)

TAURUS SIGMAX (Distribution Line Analyser)

MOQ : 1 Unit

TAURUS SIGMAX (Distribution Line Analyser) Specification

  • Usage & Applications
  • Distribution line diagnostics, voltage and frequency measurement, fault detection
  • Pressure
  • Atmospheric
  • Resistant Feature
  • Shock and Dust Resistant
  • Accuracy
  • 1.5%
  • Material
  • High Grade Plastic
  • Measuring Voltage Range
  • 10V to 500V
  • Frequency (MHz)
  • 50 Hz
  • Insulation Box
  • Yes
  • Protection System
  • Overload and Short Circuit Protection
  • Size
  • Standard
  • Color
  • Black & Grey
  • Dimension (L*W*H)
  • 270 mm x 180 mm x 120 mm
  • Weight
  • 1.8 Kg
 

TAURUS SIGMAX (Distribution Line Analyser) Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 1 Week
 

About TAURUS SIGMAX (Distribution Line Analyser)

The SIGMAX is a revolutionary innovative system significantly minimizes the distribution line downtime and overall line maintenance time. SIGMAX is the third generation, one of its kind product that works on the principle of multiple pulse echo co-relation technique, using advanced matrix processors. A single system offers a cost effective monitoring of all AC overhead de-energized lines from 11kv to33kv, providing accurate information on all faults and line signature analysis, which give data of all inhomogeneous points.

Features

  • Flexibility in utility and application - Portable system that can be used on any de-energised line from 11kv to 33kV AC lines.
  • Auto calibrated system - Requires no parameter input or presetting. Extremely simple operation.
  • Fault resolution - of +/- 50 meters throughout the range of 99.9 kilometres.
  • Range: up to 99.9kms
  • Outputs: Printout in 4 formats, Graphic LCD display & Complete Analysis data to Laptop loaded with TADMA Software



Advanced Protection and Durability

TAURUS SIGMAX is engineered with comprehensive overload and short circuit protection, ensuring both the user and the equipment remain safe during operation. Its robust insulation box and high-grade plastic construction provide exceptional resistance to shocks and dust, making it dependable for both indoor and outdoor applications. The devices sound engineering promises durability and reliable performance over time.


Precise Distribution Line Diagnostics

Equipped to measure voltage in the range of 10V to 500V and operating at 50 Hz, TAURUS SIGMAX delivers accurate diagnostics with an impressive 1.5% accuracy. It allows professionals to confidently detect faults, monitor voltage levels, and assess the distribution lines overall health, contributing to efficient and reliable electrical network maintenance.

FAQs of TAURUS SIGMAX (Distribution Line Analyser):


Q: How is the TAURUS SIGMAX Distribution Line Analyser typically used in the field?

A: The TAURUS SIGMAX is used for analyzing distribution lines by measuring voltage and frequency, detecting electrical faults, and diagnosing line issues. Its robust protection systems enable safe operation in various settings, making it ideal for routine maintenance or quick troubleshooting on-site.

Q: What benefits does the shock and dust-resistant feature offer?

A: The shock and dust-resistant build ensures the analyser performs reliably in challenging environments, such as outdoor substations or dusty workshops. This durability reduces downtime and maintenance costs by protecting vital internal components from environmental hazards.

Q: When should I use the overload and short circuit protection features?

A: These features are automatically engaged during abnormal operating conditions, such as overloads or electrical faults, to safeguard both the device and the user. Regular operation does not require manual interventionprotection is seamlessly integrated and always active during use.

Q: What is the measuring voltage and frequency range of this analyser?

A: TAURUS SIGMAX measures voltages ranging from 10V to 500V and operates at a frequency of 50 Hz, making it suitable for various electrical distribution systems encountered in industrial and commercial applications.

Q: Where is the TAURUS SIGMAX most commonly applied?

A: It is widely utilized in electrical distribution networks for performing diagnostics, measuring voltage and frequency, and detecting faults in industrial plants, substations, and commercial facilities across India and other global markets.

Q: How accurate are the measurements provided by the device?

A: With an accuracy of 1.5%, the TAURUS SIGMAX provides reliable voltage and frequency readings, ensuring dependable information for diagnostics and maintenance tasks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Production Category

Taurus Dc Earth Fault Locator

Taurus Dc Earth Fault Locator

Minimum Order Quantity : 1 Unit

Size : Portable, handheld

Color : Yellow & Black

Usage & Applications : DC earth leakage and fault location for telecommunication, solar, battery and inverter systems

Measuring Voltage Range : 24V to 220V DC

Resistant Feature : Shock and dust resistant

TAURUS MAX-3 (Overhead EHV AC Transmission Line Analyser)

TAURUS MAX-3 (Overhead EHV AC Transmission Line Analyser)

Minimum Order Quantity : 1 Unit

Size : Handheld Portable

Color : Grey/Black

Measuring Voltage Range : Up to 800 kV AC

Resistant Feature : Dust and Water Resistant (IP54)

Taurus Preciohm Et Power Station Earth Measurement Instrument

Taurus Preciohm Et Power Station Earth Measurement Instrument

Minimum Order Quantity : 1 Unit

Size : Standard

Color : Blue

Usage & Applications : Industrial

Battery health Analyzer

Battery health Analyzer

Minimum Order Quantity : 1 Unit



Back to top